ProductProduct

G581201
G581201
Lead Standard 12 leads Input Circuit Built-in defibrillator protection Acquisition Mode Simultaneous 12 leads acquisition Measurement Range ±5mVpp Time Constant ≥3.2s Frequency Response 0.05Hz~150Hz (-3dB) Sensitivity 2.5, 5, 10, 20 mm/mV Input Impedance ≥50MΩ Input Circuit Current <0.05µA Noise Level <15µVp-p Anti Baseline Drift   Automatic Patient Current Leakage <10µA (220V-240V) Filter EMG Filter:25 Hz / 30 Hz / 40Hz DFT Filter: 0.05 Hz / 0.15 Hz / 0.25 Hz /0.32 Hz / 0.5 Hz /0.67Hz/ ADS AC Filter : 50 / 60Hz Low Pass Filter:75 Hz /100 Hz /150Hz CMRR 100dB Recording Mode Automatic: 12CH, 6CH×2, 3CH×4, 3CH×4+3R Manual: 12CH, 6CH, 3CH, 1CH+1R, 1CH Rhythm: Any lead selectable Recording System Thermal matrix printing Recording Paper  Roll: 210mm×30m Z-fold: 216mm×295mm×100 sheets Paper Speed 5 mm/s,6.25mm/s, 10 mm/s,12.5 mm/s, 25 mm/s, 50mm/s Display  800×480 pixel TFT LCD Interface Network interface, USB Master/Slave, SD card Safety Standard IEC I/CF Sample Rate Normal:1000sps/channel Pacemaker: 10,000sps/channel Pacemaker Detection ≥± 2 mV ≥± 0.1 ms Dimension  435mm×335mm×98mm Weight 4Kg(include battery) Power Supply AC:100~240V, 50/60Hz, 70VA~100VA DC:14.8V/4400mAh, built-in lithium battery MicrosoftInternetExplorer402DocumentNotSpecified7.8 磅Normal0
>>More
G58601
G58601
Lead Standard 12 leads Input Circuit Built-in defibrillator protection Acquisition Mode Simultaneous 12 leads acquisition Measurement Range ±5mVpp Time Constant ≥3.2s Frequency Response 0.05Hz~150Hz (-3dB) Sensitivity 2.5, 5, 10, 20 mm/mV Input Impedance ≥50MΩ Input Circuit Current <0.05µA Noise Level <15µVp-p Anti Baseline Drift   Automatic Patient Current Leakage <10µA (220V-240V) Filter EMG Filter:25 Hz / 30 Hz / 40Hz DFT Filter: 0.05 Hz / 0.15 Hz / 0.25 Hz /0.32 Hz / 0.5 Hz /0.67Hz/ ADS AC Filter : 50 / 60Hz Low Pass Filter:75 Hz /100 Hz /150Hz CMRR 100dB Recording Mode Automatic: 3CH, 1CH+1R Manual: 3CH, 1CH+1R, 1CH Rhythm: Any lead selectable Recording System Thermal matrix printing Recording Paper  Roll: 110mm×20m Paper Speed 5 mm/s,6.25mm/s, 10 mm/s,12.5 mm/s, 25 mm/s, 50mm/s Display  800×480 pixel TFT LCD Interface Network interface, USB Master/Slave, SD card Safety Standard IEC I/CF Sample Rate Normal:1000sps/channel Pacemaker: 10,000sps/channel Pacemaker Detection ≥± 2 mV ≥± 0.1 ms Dimension  310mm×244mm×65mm Weight 2.25Kg(include battery) Power Supply AC:100~240V, 50/60Hz, 30VA~100VA DC:14.8V/2200mAh, built-in lithium battery MicrosoftInternetExplorer402DocumentNotSpecified7.8 磅Normal0
>>More
G58301
G58301
Lead Standard 12 leads Input Circuit Built-in defibrillator protection Acquisition Mode Simultaneous 12 leads acquisition Measurement Range ±5mVpp Time Constant ≥3.2s Frequency Response 0.05Hz~150Hz (-3dB) Sensitivity 2.5, 5, 10, 20 mm/mV Input Impedance ≥50MΩ Input Circuit Current <0.05µA Noise Level <15µVp-p Anti Baseline Drift   Automatic Patient Current Leakage <10µA (220V-240V) Filter EMG Filter:25 Hz / 30 Hz / 40Hz DFT Filter: 0.05 Hz / 0.15 Hz / 0.25 Hz /0.32 Hz / 0.5 Hz /0.67Hz/ ADS AC Filter : 50 / 60Hz Low Pass Filter:75 Hz /100 Hz /150Hz CMRR 100dB Recording Mode Automatic: 3CH, 1CH+1R Manual: 3CH, 1CH+1R, 1CH Rhythm: Any lead selectable Recording System Thermal matrix printing Recording Paper  Roll: 80mm×20m Paper Speed 5 mm/s,6.25mm/s, 10 mm/s,12.5 mm/s, 25 mm/s, 50mm/s Display  800×480 pixel TFT LCD Interface Network interface, USB Master/Slave, SD card Safety Standard IEC I/CF Sample Rate Normal:1000sps/channel Pacemaker: 10,000sps/channel Pacemaker Detection ≥± 2 mV ≥± 0.1 ms Dimension  310mm×244mm×65mm Weight 2.25Kg(include battery) Power Supply AC:100~240V, 50/60Hz, 30VA~100VA DC:14.8V/2200mAh, built-in lithium battery  
>>More