G3S Multi-parameter patient monitor
G3S Multi-parameter patient monitor
ECG Heart rate(HR) Measurement range: 30BPM ~ 300BPM; Accuracy: 1 BPM or ±1 %. Heart rate alarm settings And tolerance: upper limit (60 ~ 300) bpm; tolerance::± 10% Lower limit (10 ~ 200) bpm; tolerance : ± 10% Noise level: ≤ 30μV ECG frequency response: filtering methods: (1 ~ 25) HzNon-filtered mode: (0.05 ~ 100) Hz The ECG Input circuit current: ≤ 0.1μAECG sensitivity: continuous adjustable The scanning speed of the sub-file and error:Scan rate can be divided into three files for selection: 12.5mm / s, 25mm / s, 50mm / sThe error of scanning rate: ≤ ± 10%   NIBP Measurement range: Systolic(SBP):(5.3 ~ 36.0)kPa,or(40 ~ 270 )mmHg Diastolic (DBP):(2.7 ~ 26.7)kPa,or(20 ~ 200 )mmHg Mean (MAP):(4.0 ~ 29.3)kPa,or(30 ~ 220 )mmHg Accuracy : ≤ ± 0.4 kPa (3 mmHg) or ±2%,   IBP Measurement range: -1.3~40KPa(-10 ~ 300mmHg) Channel: 2 channelsTransducer sensitivity: 5MV/V/mmHg Unit display: kPa or mmHg( selectable)   Respiration Rate Measurement range: 0 BPM ~ 120 BPM; Accuracy: ±1 BPM or ±5 %   Temperature Number of channels: 2 Temperature probe configuration: Intracavitary probe: 1 unit; Surface probe: 1 unit Measurement range: 25.0 ℃~ 45.0℃ Accuracy: ± 0.2 ℃ Response time: ≤ 3 min.   SpO2     Display type: Waveform, data     Measurement range: 0~100% Resolution: 1 BPM Pulse rate range: 30~250bpm  Accuracy: ±1bpm     Pulse Rate Measurement range: (30 ~ 250)bpm; Accuracy: 1BPM or ±2%   Trend review: Can Review history data of 360 hours   CO2: Measurement range: 0﹪ ~ 10.0﹪ ( Carbon dioxide inhalation and carbon dioxide exhalation) Accuracy: ±2mmHg(<5﹪ Measured values) 10﹪(>5﹪ Measured values)   Standard configuration ECG, NIBP, SpO2, HR/PR, 2-RESP, 2-TEMP, rechargeable battery Optional configuration Built-in printer, Nellcor SpO2,2-IBP, ETCO2(main stream or side stream), Wireless network, Wall Mount, Moving cart, 12 volts Power supply
>>More
G3M Multi-parameter patient monitor
G3M Multi-parameter patient monitor
ECG Heart rate(HR) Measurement range: 30BPM ~ 300BPM; Accuracy: 1 BPM or ±1 %. Heart rate alarm settings And tolerance: upper limit (60 ~ 300) bpm; tolerance::± 10% Lower limit (10 ~ 200) bpm; tolerance : ± 10% Noise level: ≤ 30μV ECG frequency response: filtering methods: (1 ~ 25) HzNon-filtered mode: (0.05 ~ 100) Hz The ECG Input circuit current: ≤ 0.1μAECG sensitivity: continuous adjustable The scanning speed of the sub-file and error:Scan rate can be divided into three files for selection: 12.5mm / s, 25mm / s, 50mm / sThe error of scanning rate: ≤ ± 10%   NIBP Measurement range:     Systolic(SBP):(5.3 ~ 36.0)kPa,or(40 ~ 270 )mmHg     Diastolic (DBP):(2.7 ~ 26.7)kPa,or(20 ~ 200 )mmHg   Mean (MAP):(4.0 ~ 29.3)kPa,or(30 ~ 220 )mmHg Accuracy : ≤ ± 0.4 kPa (3 mmHg) or ±2%,   IBP Measurement range: -1.3~40KPa(-10 ~ 300mmHg) Channel: 2 channelsTransducer sensitivity: 5MV/V/mmHg Unit display: kPa or mmHg( selectable)   Respiration Rate Measurement range: 0 BPM ~ 120 BPM; Accuracy: ±1 BPM or ±5 %   Temperature Number of channels: 2 Temperature probe configuration: Intracavitary probe: 1 unit; Surface probe: 1 unit Measurement range: 25.0 ℃~ 45.0℃ Accuracy: ± 0.2 ℃ Response time: ≤ 3 min.   SpO2      Display type: Waveform, data      Measurement range: 0~100%  Resolution: 1 BPM  Pulse rate range: 30~250bpm Accuracy: ±1bpm   Pulse Rate Measurement range: (30 ~ 250)bpm; Accuracy: 1BPM or ±2%     Trend review: Can Review history data of 360 hours   CO2: Measurement range: 0﹪ ~ 10.0﹪ ( Carbon dioxide inhalation and carbon dioxide exhalation) Accuracy: ±2mmHg(<5﹪ Measured values) 10﹪(>5﹪ Measured values)   Standard configuration ECG, NIBP,  SpO2, HR/PR, 2-RESP, 2-TEMP, rechargeable battery. Optional configuration Built-in printer, Nellcor SpO2,2-IBP, ETCO2(main stream or side stream), CO, AG,Wireless network, Wall Mount, Moving cart, 12 volts Power supply
>>More
G3N Multi-parameter patient monitor
G3N Multi-parameter patient monitor
ECG Heart rate(HR) Measurement range: 30BPM ~ 350BPM; Accuracy: 1 BPM or ±1 %. Heart rate alarm settings And tolerance: upper limit (60 ~ 300) bpm; tolerance::± 10% Lower limit (10 ~ 200) bpm; tolerance : ± 10% Noise level: ≤ 30μV ECG frequency response: filtering methods: (1 ~ 25) HzNon-filtered mode: (0.05 ~ 100) Hz The ECG Input circuit current: ≤ 0.1μAECG sensitivity: continuous adjustable The scanning speed of the sub-file and error: Scan rate can be divided into three files for selection: 12.5mm / s, 25mm / s, 50mm / sThe error of scanning rate: ≤ ± 10%     NIBP Measurement range: Systolic(SBP):(5.3 ~ 36.0)kPa,or(40 ~ 270 )mmHg Diastolic (DBP):(2.7 ~ 26.7)kPa,or(20 ~ 200 )mmHg Mean (MAP):(4.0 ~ 29.3)kPa,or(30 ~ 220 )mmHg Accuracy : ≤ ± 0.4 kPa (3 mmHg) or ±2%     IBP Measurement range: -1.3~40KPa(-10 ~ 300mmHg) Channel: 2 channelsTransducer sensitivity: 5MV/V/mmHg Unit display: kPa or mmHg( selectable) Respiration Rate Measurement range: 0 BPM ~ 120 BPM; Accuracy: ±1 BPM or ±5 %   Temperature Number of channels: 2 Temperature probe configuration: Intracavitary probe: 1 unit; Surface probe: 1 unit Measurement range: 25.0 ℃~ 45.0℃ Accuracy: ± 0.2 ℃ Response time: ≤ 3 min.   GMI SpO2     Display type: Waveform, data     Measurement range: 0~100% Resolution: 1 BPM Pulse rate range: 30~250bpm Accuracy: ±1bpm   Pulse Rate Measurement range: (30 ~ 250)bpm; Accuracy: 1BPM or ±2% Trend review: Can Review history data of 360 hours   CO2 Measurement range: 0﹪ ~ 10.0﹪ ( Carbon dioxide inhalation and carbon dioxide exhalation) Accuracy: ±2mmHg(<5﹪ Measured values) 10﹪(>5﹪ Measured values)   Standard configuration ECG, NIBP,  SpO2, HR/PR, 2-RESP, 2-TEMP, rechargeable battery. Optional configuration Built-in printer, GMI SpO2, Nellcor SpO2,2-IBP, ETCO2(main stream or side  
>>More
G3L Multi-parameter patient monitor
G3L Multi-parameter patient monitor
ECG Lead output: 3 wires/5 wires ECG cable Lead section: I, II, III, aVR, aVL, aVF, V Gain selection: ×1/4, ×1/2, ×1, ×2, ×4 and automatic Scan speed: 6.25 mm/s 、12.5 mm/s 、25 mm/s、50mm/s Heart rate range: 15-300bpm ECG calibration: ± 1 mvHeart rate accuracy: ± 1%   NIBP Philosophy: Oscillometric method Measurement type: adult, pediatric, neonate Measurement parameter: Systolic, Diastolic, Mean Measurement method: manual, automatic, continuous measurement Unit: mmHg/kPa selectable Accuracy: ±2 or 3mmHg   SpO2     Display type: Waveform, data      Measurement range: 0~100% Resolution: 1 BPM Pulse rate range: 30~250bpm Accuracy: ±1bpm                                                                             Temperature Number of channel: 2 channels, measure surface and cavity temperature simultaneously Resolution: 0.1℃ Display: T1, T2, △T   Respiration Thoracic impedance & nasal tube double method selectable Measurement range: 0~120bpm Accuracy: ±1bpm Resolution: 1bpm   ETCO2 (Option) Measuring Method: main/side stream typeMeasurement range: 0%-10.0% Accuracy: ±2mmHg    2-IBP (Invasive blood pressure) (Option) Measurement range: -10-300mmHgChannel: max 4 channels Accuracy:±1mmHg or ±2%Transducer sensitivity: 5uV/V/mmHg Pressure label: ART、CVP、RVP、LAP、RAP、PAP、ICP、LVP   Cardiac Output (Option) Measuring Method: thermodilution Blood temperature measurement and alarm range: 23 ℃~ 43℃ Unit: degrees Celsius ℃ or Fahrenheit ℉ Resolution: 0.1℃ Cardiac output measurement range: 0.1L/min ~ 20.0 L/min Accuracy: ±0.2 L/min or ±5% Power requirement: 100~240VAC, 50/60Hz  
>>More
G3H Multi-parameter patient monitor
G3H Multi-parameter patient monitor
ECG Heart rate(HR) Measurement range: 30BPM ~ 300BPM; Accuracy: 1 BPM or ±1 %. Heart rate alarm settings And tolerance: upper limit (60 ~ 300) bpm; tolerance::± 10% Lower limit (10 ~ 200) bpm; tolerance : ± 10% Noise level: ≤ 30μV ECG frequency response: filtering methods: (1 ~ 25) HzNon-filtered mode: (0.05 ~ 100) Hz The ECG Input circuit current: ≤ 0.1μAECG sensitivity: continuous adjustable The scanning speed of the sub-file and error:Scan rate can be divided into three files for selection: 12.5mm / s, 25mm / s, 50mm / sThe error of scanning rate: ≤ ± 10%   NIBP Measurement range: Systolic(SBP):(5.3 ~ 36.0)kPa,or(40 ~ 270 )mmHg Diastolic (DBP):(2.7 ~ 26.7)kPa,or(20 ~ 200 )mmHg Mean (MAP):(4.0 ~ 29.3)kPa,or(30 ~ 220 )mmHg Accuracy : ≤ ± 0.4 kPa (3 mmHg) or ±2%,   IBP Measurement range: -1.3~40KPa(-10 ~ 300mmHg) Channel: 2 channelsTransducer sensitivity: 5MV/V/mmHg Unit display: kPa or mmHg( selectable)   Respiration Rate Measurement range: 0 BPM ~ 120 BPM; Accuracy: ±1 BPM or ±5 %   Temperature Number of channels: 2 Temperature probe configuration: Intracavitary probe: 1 unit; Surface probe: 1 unit Measurement range: 25.0 ℃~ 45.0℃ Accuracy: ± 0.2 ℃ Response time: ≤ 3 min.   SpO2     Display type: Waveform, data     Measurement range: 0~100% Resolution: 1 BPM Pulse rate range: 30~250bpm  Accuracy: ±1bpm     Pulse Rate Measurement range: (30 ~ 250)bpm; Accuracy: 1BPM or ±2%   Trend review: Can Review history data of 360 hours   CO2: Measurement range: 0﹪ ~ 10.0﹪ ( Carbon dioxide inhalation and carbon dioxide exhalation) Accuracy: ±2mmHg(<5﹪ Measured values) 10﹪(>5﹪ Measured values)   Standard configuration ECG, NIBP, SpO2, HR/PR, 2-RESP, 2-TEMP, rechargeable battery Optional configuration Built-in printer, Nellcor SpO2,2-IBP, ETCO2(main stream or side stream), Wireless network, Wall Mount, Moving cart, 12 volts Power supply  
>>More
G3G Multi-parameter patient monitor
G3G Multi-parameter patient monitor
ECG Heart rate(HR) Measurement range: 30BPM ~ 300BPM; Accuracy: 1 BPM or ± 1 %. Heart rate alarm settings And tolerance: upper limit (60 ~ 300) bpm; tolerance::± 10% Lower limit (10 ~ 200) bpm; tolerance : ± 10% Noise level: ≤ 30μV ECG frequency response: filtering methods: (1 ~ 25) HzNon-filtered mode: (0.05 ~ 100) Hz The ECG Input circuit current: ≤ 0.1μAECG sensitivity: continuous adjustable The scanning speed of the sub-file and error:Scan rate can be divided into three files for selection: 12.5mm / s, 25mm / s, 50mm / sThe error of scanning rate: ≤ ± 10%   NIBP Measurement range: Systolic(SBP):(5.3 ~ 36.0)kPa,or(40 ~ 270 )mmHg Diastolic (DBP):(2.7 ~ 26.7)kPa,or(20 ~ 200 )mmHg Mean (MAP):(4.0 ~ 29.3)kPa,or(30 ~ 220 )mmHg Accuracy : ≤ ± 0.4 kPa (3 mmHg) or ±2%,   IBP Measurement range: -1.3~40KPa(-10 ~ 300mmHg) Channel: 2 channelsTransducer sensitivity: 5MV/V/mmHg Unit display: kPa or mmHg( selectable)   Respiration Rate Measurement range: 0 BPM ~ 120 BPM; Accuracy: ±1 BPM or ±5 %   Temperature Number of channels: 2 Temperature probe configuration: Intracavitary probe: 1 unit; Surface probe: 1 unit Measurement range: 25.0 ℃~ 45.0℃ Accuracy: ± 0.2 ℃ Response time: ≤ 3 min.     SpO2     Display type: Waveform, data     Measurement range: 0~100% Resolution: 1 BPM  Pulse rate range: 30~250bpm  Accuracy: ±1bpm     Pulse Rate Measurement range: (30 ~ 250)bpm; Accuracy: 1BPM or ±2%   Trend review: Can Review history data of 360 hours   CO2: Measurement range: 0﹪ ~ 10.0﹪ ( Carbon dioxide inhalation and carbon dioxide exhalation) Accuracy: ±2mmHg(<5﹪ Measured values) 10﹪(>5﹪ Measured values)   Standard configuration ECG, NIBP,SpO2, HR/PR, 2-RESP, 2-TEMP, rechargeable battery. Optional configuration Built-in printer, Nellcor SpO2,2-IBP, ETCO2(main stream or side stream), CO, AG,Wireless network, Wall Mount, Moving cart, 12 volts Power supply
>>More
G3F Multi-parameter patient monitor
G3F Multi-parameter patient monitor
ECG Heart rate(HR) Measurement range: 30BPM ~ 300BPM; Accuracy: 1 BPM or ±1 %. Heart rate alarm settings And tolerance: upper limit (60 ~ 300) bpm; tolerance::± 10% Lower limit (10 ~ 200) bpm; tolerance : ± 10% Noise level: ≤ 30μV ECG frequency response: filtering methods: (1 ~ 25) HzNon-filtered mode: (0.05 ~ 100) Hz The ECG Input circuit current: ≤ 0.1μAECG sensitivity: continuous adjustable The scanning speed of the sub-file and error:Scan rate can be divided into three files for selection: 12.5mm / s, 25mm / s, 50mm / sThe error of scanning rate: ≤ ± 10%   NIBP Measurement range: Systolic(SBP):(5.3 ~ 36.0)kPa,or(40 ~ 270 )mmHg Diastolic (DBP):(2.7 ~ 26.7)kPa,or(20 ~ 200 )mmHg Mean (MAP):(4.0 ~ 29.3)kPa,or(30 ~ 220 )mmHg Accuracy : ≤ ± 0.4 kPa (3 mmHg) or ±2%,   IBP Measurement range: -1.3~40KPa(-10 ~ 300mmHg) Channel: 2 channelsTransducer sensitivity: 5MV/V/mmHg Unit display: kPa or mmHg( selectable)   Respiration Rate Measurement range: 0 BPM ~ 120 BPM; Accuracy: ±1 BPM or ±5 %   Temperature Number of channels: 2 Temperature probe configuration: Intracavitary probe: 1 unit; Surface probe: 1 unit Measurement range: 25.0 ℃~ 45.0℃ Accuracy: ± 0.2 ℃ Response time: ≤ 3 min.   SpO2     Display type: Waveform, data     Measurement range: 0~100%  Resolution: 1 BPM Pulse rate range: 30~250bpm  Accuracy: ±1bpm   Pulse Rate Measurement range: (30 ~ 250)bpm; Accuracy: 1BPM or ±2%   Trend review: Can Review history data of 360 hours   CO2: Measurement range: 0﹪ ~ 10.0﹪ ( Carbon dioxide inhalation and carbon dioxide exhalation) Accuracy: ±2mmHg(<5﹪ Measured values) 10﹪(>5﹪ Measured values)   Standard configuration: ECG+ RESP+TEMP+NIBP+T SPO2 ( built in High-energy rechargeable battery) Optional configuration: ETCO2, printer,2-IBP, Wall Mount, Trolly It is suitable for central monitor system, connect to each workstation bedside machine: 1-16 units, expand to 16 workstations.
>>More
G3D Multi-parameter patient monitor
G3D Multi-parameter patient monitor
ECG Heart rate(HR) Measurement range: 30BPM ~ 300BPM; Accuracy: 1 BPM or ±1 %. Heart rate alarm settings And tolerance: upper limit (60 ~ 300) bpm; tolerance::± 10% Lower limit (10 ~ 200) bpm; tolerance : ± 10% Noise level: ≤ 30μV ECG frequency response: filtering methods: (1 ~ 25) HzNon-filtered mode: (0.05 ~ 100) Hz The ECG Input circuit current: ≤ 0.1μAECG sensitivity: continuous adjustable The scanning speed of the sub-file and error: Scan rate can be divided into three files for selection: 12.5mm / s, 25mm / s, 50mm / sThe error of scanning rate: ≤ ± 10%       NIBP Measurement range: Systolic(SBP):(5.3 ~ 36.0)kPa,or(40 ~ 270 )mmHg Diastolic (DBP):(2.7 ~ 26.7)kPa,or(20 ~ 200 )mmHg Mean (MAP):(4.0 ~ 29.3)kPa,or(30 ~ 220 )mmHg Accuracy : ≤ ± 0.4 kPa (3 mmHg) or ±2%,   IBP Measurement range: -1.3~40KPa(-10 ~ 300mmHg) Channel: 2 channelsTransducer sensitivity: 5MV/V/mmHg Unit display: kPa or mmHg( selectable)   Respiration Rate Measurement range: 0 BPM ~ 120 BPM; Accuracy: ±1 BPM or ±5 %   Temperature Number of channels: 2 Temperature probe configuration: Intracavitary probe: 1 unit; Surface probe: 1 unit Measurement range: 25.0 ℃~ 45.0℃ Accuracy: ± 0.2 ℃ Response time: ≤ 3 min.   SpO2     Display type: Waveform, data     Measurement range: 0~100%  Resolution: 1 BPM Pulse rate range: 30~250bpm Accuracy: ±1bpm   Pulse Rate Measurement range: (30 ~ 250)bpm; Accuracy: 1BPM or ±2%   Trend review: Can Review history data of 360 hours   CO2: Measurement range: 0﹪ ~ 10.0﹪ ( Carbon dioxide inhalation and carbon dioxide exhalation) Accuracy: ±2mmHg(<5﹪ Measured values) 10﹪(>5﹪ Measured values)   Standard configuration ECG, NIBP, SpO2, HR/PR, 2-RESP, 2-TEMP, rechargeable battery. Optional configuration Built-in printer, Nellcor SpO2,2-IBP, ETCO2(main stream or side stream), CO, AG,Wireless network, Wall Mount, Moving cart, 12 volts Power supply
>>More
G3C Multi-parameter patient monitor
G3C Multi-parameter patient monitor
ECG Heart rate(HR) Measurement range: 30BPM ~ 300BPM; Accuracy: 1 BPM or ±1 %. Heart rate alarm settings And tolerance: upper limit (60 ~ 300) bpm; tolerance::± 10% Lower limit (10 ~ 200) bpm; tolerance : ± 10% Noise level: ≤ 30μV ECG frequency response: filtering methods: (1 ~ 25) HzNon-filtered mode: (0.05 ~ 100) Hz The ECG Input circuit current: ≤ 0.1μAECG sensitivity: continuous adjustable The scanning speed of the sub-file and error:Scan rate can be divided into three files for selection: 12.5mm / s, 25mm / s, 50mm / sThe error of scanning rate: ≤ ± 10%   NIBP Measurement range:     Systolic(SBP):(5.3 ~ 36.0)kPa,or(40 ~ 270 )mmHg     Diastolic (DBP):(2.7 ~ 26.7)kPa,or(20 ~ 200 )mmHg   Mean (MAP):(4.0 ~ 29.3)kPa,or(30 ~ 220 )mmHg Accuracy : ≤ ± 0.4 kPa (3 mmHg) or ±2%,   IBP Measurement range: -1.3~40KPa(-10 ~ 300mmHg) Channel: 2 channelsTransducer sensitivity: 5MV/V/mmHg Unit display: kPa or mmHg( selectable)   Respiration Rate Measurement range: 0 BPM ~ 120 BPM; Accuracy: ±1 BPM or ±5 %   Temperature Number of channels: 2 Temperature probe configuration: Intracavitary probe: 1 unit; Surface probe: 1 unit Measurement range: 25.0 ℃~ 45.0℃ Accuracy: ± 0.2 ℃ Response time: ≤ 3 min.   SpO2      Display type: Waveform, data      Measurement range: 0~100%  Resolution: 1 BPM  Pulse rate range: 30~250bpm Accuracy: ±1bpm   Pulse Rate Measurement range: (30 ~ 250)bpm; Accuracy: 1BPM or ±2%     Trend review: Can Review history data of 360 hours   CO2: Measurement range: 0﹪ ~ 10.0﹪ ( Carbon dioxide inhalation and carbon dioxide exhalation) Accuracy: ±2mmHg(<5﹪ Measured values) 10﹪(>5﹪ Measured values)   Standard configuration ECG, NIBP,  SpO2, HR/PR, 2-RESP, 2-TEMP, rechargeable battery. Optional configuration Built-in printer, Nellcor SpO2,2-IBP, ETCO2(main stream or side stream), CO, AG,Wireless network, Wall Mount, Moving cart, 12 volts Power supply
>>More