G3N Veterinary Monitor
G3N Veterinary Monitor
ECG Heart rate(HR) Measurement range: 30BPM ~ 350BPM; Accuracy: 1 BPM or ±1 %. Heart rate alarm settings And tolerance: upper limit (60 ~ 300) bpm; tolerance::± 10% Lower limit (10 ~ 200) bpm; tolerance : ± 10% Noise level: ≤ 30μV ECG frequency response: filtering methods: (1 ~ 25) HzNon-filtered mode: (0.05 ~ 100) Hz The ECG Input circuit current: ≤ 0.1μAECG sensitivity: continuous adjustable The scanning speed of the sub-file and error: Scan rate can be divided into three files for selection: 12.5mm / s, 25mm / s, 50mm / sThe error of scanning rate: ≤ ± 10%     NIBP Measurement range: Systolic(SBP):(5.3 ~ 36.0)kPa,or(40 ~ 270 )mmHg Diastolic (DBP):(2.7 ~ 26.7)kPa,or(20 ~ 200 )mmHg Mean (MAP):(4.0 ~ 29.3)kPa,or(30 ~ 220 )mmHg Accuracy : ≤ ± 0.4 kPa (3 mmHg) or ±2%     IBP Measurement range: -1.3~40KPa(-10 ~ 300mmHg) Channel: 2 channelsTransducer sensitivity: 5MV/V/mmHg Unit display: kPa or mmHg( selectable) Respiration Rate Measurement range: 0 BPM ~ 120 BPM; Accuracy: ±1 BPM or ±5 %   Temperature Number of channels: 2 Temperature probe configuration: Intracavitary probe: 1 unit; Surface probe: 1 unit Measurement range: 25.0 ℃~ 45.0℃ Accuracy: ± 0.2 ℃ Response time: ≤ 3 min.   GMI SpO2     Display type: Waveform, data     Measurement range: 0~100% Resolution: 1 BPM Pulse rate range: 30~250bpm Accuracy: ±1bpm   Pulse Rate Measurement range: (30 ~ 250)bpm; Accuracy: 1BPM or ±2% Trend review: Can Review history data of 360 hours   CO2 Measurement range: 0﹪ ~ 10.0﹪ ( Carbon dioxide inhalation and carbon dioxide exhalation) Accuracy: ±2mmHg(<5﹪ Measured values) 10﹪(>5﹪ Measured values)   Standard configuration ECG, NIBP,  SpO2, HR/PR, 2-RESP, 2-TEMP, rechargeable battery. Optional configuration Built-in printer, GMI SpO2, Nellcor SpO2,2-IBP, ETCO2(main stream or side
>>More
G3H Veterinary Monitor
G3H Veterinary Monitor
ECG Heart rate(HR) Measurement range: 30BPM ~ 350BPM; Accuracy: 1 BPM or ±1 %. Heart rate alarm settings And tolerance: upper limit (60 ~ 300) bpm; tolerance::± 10% Lower limit (10 ~ 200) bpm; tolerance : ± 10% Noise level: ≤ 30μV ECG frequency response: filtering methods: (1 ~ 25) HzNon-filtered mode: (0.05 ~ 100) Hz The ECG Input circuit current: ≤ 0.1μAECG sensitivity: continuous adjustable The scanning speed of the sub-file and error:Scan rate can be divided into three files for selection: 12.5mm / s, 25mm / s, 50mm / sThe error of scanning rate: ≤ ± 10%   NIBP Measurement range: Systolic(SBP):(5.3 ~ 36.0)kPa,or(40 ~ 270 )mmHg Diastolic (DBP):(2.7 ~ 26.7)kPa,or(20 ~ 200 )mmHg Mean (MAP):(4.0 ~ 29.3)kPa,or(30 ~ 220 )mmHg Accuracy : ≤ ± 0.4 kPa (3 mmHg) or ±2%,   IBP Measurement range: -1.3~40KPa(-10 ~ 300mmHg) Channel: 2 channelsTransducer sensitivity: 5MV/V/mmHg Unit display: kPa or mmHg( selectable)   Respiration Rate Measurement range: 0 BPM ~ 120 BPM; Accuracy: ±1 BPM or ±5 %   Temperature Number of channels: 2 Temperature probe configuration: Intracavitary probe: 1 unit; Surface probe: 1 unit Measurement range: 25.0 ℃~ 45.0℃ Accuracy: ± 0.2 ℃ Response time: ≤ 3 min.   MasimoSET SpO2                                                                                                              GMI SpO2     Measurement range: (1 ~ 100) %                                                                                    Display type: Waveform, data     Saturation Accuracy:  70%~100%±2/3 digits                                                                 Measurement range: 0~100%                                        0%~69% unspecified                                                                  Resolution: 1 BPM Saturation Resolution:  1%                                                                                               Pulse rate range: 30~250bpm Perfusion Index range: 0.02%~20%                                                                               Accuracy: ±1bpm Pulse Rate range :  During No Motion Condition:25 to 240±3 digits                                     During Motion Condition:25 to 240±5 digits Pulse Rate Resolution : 1bpm Low Perfusion Performance:  >0.02% Pulse Amplitude    Saturtion±2digits And Transmission%>5%    Pulse Rate ±3digits   Pulse Rate Measurement range: (30 ~ 250)bpm; Accuracy: 1BPM or ±2%   Trend review: Can Review history data of 360 hours   CO2: Measurement range: 0﹪ ~ 10.0﹪ ( Carbon dioxide inhalation and carbon dioxide exhalation) Accuracy: ±2mmHg(<5﹪ Measured values) 10﹪(>5﹪ Measured values)   Standard configuration ECG, NIBP, MasimoSET SpO2, HR/PR, 2-RESP, 2-TEMP, rechargeable battery Optional configuration Built-in printer, GMI SpO2, Nellcor SpO2,2-IBP, ETCO2(main stream or side stream), Wireless network, Wall Mount, Moving cart, 12 volts Power supply
>>More
G3G Veterinary Monitor
G3G Veterinary Monitor
ECG Heart rate(HR) Measurement range: 30BPM ~ 350BPM; Accuracy: 1 BPM or ± 1 %. Heart rate alarm settings And tolerance: upper limit (60 ~ 300) bpm; tolerance::± 10% Lower limit (10 ~ 200) bpm; tolerance : ± 10% Noise level: ≤ 30μV ECG frequency response: filtering methods: (1 ~ 25) HzNon-filtered mode: (0.05 ~ 100) Hz The ECG Input circuit current: ≤ 0.1μAECG sensitivity: continuous adjustable The scanning speed of the sub-file and error:Scan rate can be divided into three files for selection: 12.5mm / s, 25mm / s, 50mm / sThe error of scanning rate: ≤ ± 10%   NIBP Measurement range: Systolic(SBP):(5.3 ~ 36.0)kPa,or(40 ~ 270 )mmHg Diastolic (DBP):(2.7 ~ 26.7)kPa,or(20 ~ 200 )mmHg Mean (MAP):(4.0 ~ 29.3)kPa,or(30 ~ 220 )mmHg Accuracy : ≤ ± 0.4 kPa (3 mmHg) or ±2%,   IBP Measurement range: -1.3~40KPa(-10 ~ 300mmHg) Channel: 2 channelsTransducer sensitivity: 5MV/V/mmHg Unit display: kPa or mmHg( selectable)   Respiration Rate Measurement range: 0 BPM ~ 120 BPM; Accuracy: ±1 BPM or ±5 %   Temperature Number of channels: 2 Temperature probe configuration: Intracavitary probe: 1 unit; Surface probe: 1 unit Measurement range: 25.0 ℃~ 45.0℃ Accuracy: ± 0.2 ℃ Response time: ≤ 3 min.     MasimoSET SpO2                                                                                                              GMI SpO2     Measurement range: (1 ~ 100) %                                                                                    Display type: Waveform, data     Saturation Accuracy:  70%~100%±2/3 digits                                                                 Measurement range: 0~100%                                        0%~69% unspecified                                                                  Resolution: 1 BPM Saturation Resolution:  1%                                                                                               Pulse rate range: 30~250bpm Perfusion Index range: 0.02%~20%                                                                               Accuracy: ±1bpm Pulse Rate range :  During No Motion Condition:25 to 240±3 digits                                     During Motion Condition:25 to 240±5 digits Pulse Rate Resolution : 1bpm Low Perfusion Performance:  >0.02% Pulse Amplitude    Saturtion±2digits And Transmission%>5%    Pulse Rate ±3digits   Pulse Rate Measurement range: (30 ~ 250)bpm; Accuracy: 1BPM or ±2%   Trend review: Can Review history data of 360 hours   CO2: Measurement range: 0﹪ ~ 10.0﹪ ( Carbon dioxide inhalation and carbon dioxide exhalation) Accuracy: ±2mmHg(<5﹪ Measured values) 10﹪(>5﹪ Measured values)   Standard configuration ECG, NIBP, MasimoSET SpO2, HR/PR, 2-RESP, 2-TEMP, rechargeable battery. Optional configuration Built-in printer, GMI SpO2, Nellcor SpO2,2-IBP, ETCO2(main stream or side stream), CO, AG,Wireless network, Wall Mount, Moving cart, 12 volts Power supply
>>More
G3D Veterinary Monitor
G3D Veterinary Monitor
ECG Heart rate(HR) Measurement range: 30BPM ~ 350BPM; Accuracy: 1 BPM or ±1 %. Heart rate alarm settings And tolerance: upper limit (60 ~ 300) bpm; tolerance::± 10% Lower limit (10 ~ 200) bpm; tolerance : ± 10% Noise level: ≤ 30μV ECG frequency response: filtering methods: (1 ~ 25) HzNon-filtered mode: (0.05 ~ 100) Hz The ECG Input circuit current: ≤ 0.1μAECG sensitivity: continuous adjustable The scanning speed of the sub-file and error: Scan rate can be divided into three files for selection: 12.5mm / s, 25mm / s, 50mm / sThe error of scanning rate: ≤ ± 10%       NIBP Measurement range: Systolic(SBP):(5.3 ~ 36.0)kPa,or(40 ~ 270 )mmHg Diastolic (DBP):(2.7 ~ 26.7)kPa,or(20 ~ 200 )mmHg Mean (MAP):(4.0 ~ 29.3)kPa,or(30 ~ 220 )mmHg Accuracy : ≤ ± 0.4 kPa (3 mmHg) or ±2%,   IBP Measurement range: -1.3~40KPa(-10 ~ 300mmHg) Channel: 2 channelsTransducer sensitivity: 5MV/V/mmHg Unit display: kPa or mmHg( selectable)   Respiration Rate Measurement range: 0 BPM ~ 120 BPM; Accuracy: ±1 BPM or ±5 %   Temperature Number of channels: 2 Temperature probe configuration: Intracavitary probe: 1 unit; Surface probe: 1 unit Measurement range: 25.0 ℃~ 45.0℃ Accuracy: ± 0.2 ℃ Response time: ≤ 3 min.    GMI SpO2     Display type: Waveform, data     Measurement range: 0~100%  Resolution: 1 BPM Pulse rate range: 30~250bpm Accuracy: ±1bpm   Pulse Rate Measurement range: (30 ~ 250)bpm; Accuracy: 1BPM or ±2%   Trend review: Can Review history data of 360 hours   CO2: Measurement range: 0﹪ ~ 10.0﹪ ( Carbon dioxide inhalation and carbon dioxide exhalation) Accuracy: ±2mmHg(<5﹪ Measured values) 10﹪(>5﹪ Measured values)   Standard configuration ECG, NIBP, SpO2, HR/PR, 2-RESP, 2-TEMP, rechargeable battery. Optional configuration Built-in printer, GMI SpO2, Nellcor SpO2,2-IBP, ETCO2(main stream or side stream), CO, AG,Wireless network, Wall Mount, Moving cart, 12 volts Power supply
>>More